Type: For manual processing
Brand: NDTQUAM
This set of chemical is concentrate , suitable for various types of automatic film developing machines to develop various types of industrial X-ray films, so as to ensure that the films display clear radiographic inspection images.
Can get processing developer:
Working fluid (38 L)
A solution 5L 2
B solution 0.5L x 2
C solution 0.5L x 2
Can get processing fixer
A solution 5L 2
B solution 1L 2
Note: the red letter label is developer
Blue letter label is fixer
Preparation of development working solution:
1. Add 26 liters of high-quality warm water
2. Slowly add all liquid a while stirring
3. Add liquid B slowly while stirring
4. Add liquid C slowly while stirring
5. Until well stirred
Preparation method of fixing solution:
1. Add 27 liters of high-quality warm water
2.Add all liquid A slowly while stirring
3. Slowly add liquid B while stirring
4. Until well stirred
Notes:
1. Do not mix fixer with developer;
2. The container for dispensing liquid medicine shall be clean;
3. This liquid has strong irritant, pay attention to protection;
4. The developing temperature control range is 28 ~ 32 ℃, which can be selected according to the model of the film developing machine;
5. The period of validity is 18 months;
6. Each set of medicine can be prepared with 38 liters of development working solution and fixation working solution respectively.